Product Details
Equipment Introduction: This equipment is suitable for dry leak detection of SF6 switchgear and ring main unit. Simultaneously evacuate the workpiece and vacuum box to ensure that the pressure difference between the inside and outside of the workpiece is not greater than 0.05 MPa. Fill the inspected workpiece with helium gas and use the vacuum box method to perform helium mass spectrometry airtightness testing. The device determines whether the inspected workpiece is qualified or unqualified. Then, the helium gas inside the inspected workpiece is recycled and reused, and finally SF6 working gas at the specified pressure is filled into the workpiece.
Main technical parameters
1. Operation method: Manual picking and placing of items (box inspection)
2. Vacuum box capacity: width 1000 * height 1750 * depth 28004900L
3. Number of products tested per box: 1-2 pieces
4. Helium filling pressure: 0-0.05MPa
5. SF6 filling pressure: 0.05-0.15MPa
6. Detection cycle: ≤ 50min
7. Detection accuracy: ≤ 3.9E-6Pa·m³/s(0.5%)
8. The detection process is fully automated and easy to operate
9. Human computer interaction interface, convenient for maintenance
10. Equipped with data storage function and traceable detection data
Previous:
: Next
Previous:
Related Products
Product Consulting
Welcome to leave us a message, we will contact us as soon as possible!